Showing posts with label chemical probes. Show all posts
Showing posts with label chemical probes. Show all posts

Tuesday, 19 December 2023

On quality criteria for covalent and degrader probes

I’ll be taking a look at H2023 (Expanding Chemical Probe Space: Quality Criteria for Covalent and Degrader Probes) in this post and this article has also been discussed In The Pipeline. I’ll primarily be discussing the quality criteria for covalent probes in this post although I’ll also comment briefly on chemical matter criteria proposed for degrader probes. The post is intended as a contribution to the important scientific discussion that the H2023 Perspective is intended to jumpstart:

We are convinced that now is the time to initiate similar efforts to achieve a consensus about quality criteria for covalently acting and degrader probes. This Perspective is intended to jumpstart this important scientific discussion.

Covalent bond formation between ligands and targets is a drug design tactic for exploiting molecular recognition elements in targets that are difficult to make beneficial contacts with.  Cysteine SH has minimal capacity to form hydrogen bonds with polar ligand atoms and the exposed nature of catalytic cysteine SH reduces its potential to make beneficial contacts with non-polar ligand atoms. One common misconception in drug discovery is that covalent bond formation between targets and ligands is necessarily irreversible and it wasn’t clear from my reading of H2023 whether the authors were aware that covalent bond formation between targets and ligands can also be reversible. In any case, it needed to be made clear that the quality criteria proposed by the authors for covalently acting small-molecule probes only apply to probes that act irreversibly.

Irreversible covalent bond formation is typically used to target non-catalytic residues and design is lot more complicated than for reversible covalent bond formation. First, IC50 values are time-dependent (there are two activity parameters: affinity and inactivation rate constant) which makes it much more difficult to assess selectivity or to elucidate SAR. Second, the transition state structural models required for modelling inactivation cannot be determined experimentally and therefore need to be calculated using computationally intensive quantum mechanical methods.

I’ll start my review with a couple of general comments. Intracellular concentration is factor that is not always fully appreciated in chemical biology and I generally recommend that people writing about chemical probes demonstrate awareness of SR2019 (Intracellular and Intraorgan Concentrations of Small Molecule Drugs: Theory, Uncertainties in Infectious Diseases and Oncology, and Promise). One a more pedantic note I cautioned against using ‘molecule’ as a synonym for ‘compound’ in my review of S2023 (Systematic literature review reveals suboptimal use of chemical probes in cell-based biomedical research) and I suggest that “covalent molecule” might be something that you don't want to see in the text of an article in a chemistry journal.

However, significant efforts need to be invested into characterizing and validating covalent molecules as a prerequisite for conclusive use in biomedical research and target validation studies.

The proposed quality criteria for covalently acting small-molecule probes are given in Figure 2 of H2023 although I’ll be commenting on the text of the article. Subscripting doesn't work well in blogger and so I'll use K.i and k.inact respectively throughout the post to denote the inhibition constant and the first order inactivation rate constant.  

I’ll start with Section 2.1 (Criteria for Assessing Potency of Covalent Probes) and my comments are italicised in red. 

When working with irreversible covalent probes, it is important to consider that target inhibition is time-dependent and therefore IC50 values, while frequently used, are a suboptimal descriptor of potency. (21) Best practice is to use k.inact (the rate of inactivation) over K.i (the affinity for the target) values instead. (22) [I recommend that values of both k.inact and K.i be reported since because this enables the extent of non-covalent target engagement by the chemical probe to be assessed. Regardless of whether binding to target is covalent or non-covalent, the concentration and affinity of substrates (as well as cofactors such as ATP) need be properly accounted for when interpreting effects of chemical probes in cell-based assays. This is a significant issue for ATP-competitive kinase inhibitors (as discussed in my review of S2023) and I recommend this tweetorial from Keith Hornberger.]

As measurement of k.inact/K.i values can be labor-intensive (or in certain cases technically impossible), IC50 values (or target engagement TE50 values) are often reported for covalent leads and used to generate structure–activity relationships (SARs). [The labor-intensive nature of the measurements is not a valid justification for a failure to measure k.inact and K.i values for a covalent chemical probe.]  Carefully designed biochemical assays used in determining IC50 values can be well-suited as surrogates for k.inact/K.i measurements. (24) [It is my understanding that the primary reason for doing this is to increase the throughput of irreversible inhibition assays for SAR optimization and I would generally be extremely wary of any IC50 value measured for an irreversible inhibitor if it had not been technically impossible to measure k.inact or K.i values for the inhibitor.]

2.2. Criteria for Assessing Covalent Probe Selectivity

We propose a selectivity factor of 30-fold in favor of the intended target of the probe compared to that of other family members or identified off-targets under comparable assay conditions. [The authors need to be clearer as to which measure of ‘activity’ they propose should be used for calculating the ratio and some justification for the ratio (why 30-fold rather than 50-fold or 25-fold?) should be given. Regardless of whether binding to target is covalent or non-covalent, the concentration and affinity of substrates (as well as cofactors such as ATP) need to be properly accounted for when assessing selectivity. It is not clear how the selectivity factor should be defined to quantify selectivity of an inhibitor that binds covalently to the target but non-covalently to off-targets. My comments on the THZ1 probe in my review of the S2023 study may be relevant.]

2.3. Chemical Matter Criteria for Covalent Probes

Ideally, the on-target activity of the covalent probe is not dominated by the reactive warhead, but the rest of the molecule provides a measurable reversible affinity for the intended target. [My view is that the reversible affinity of the probe should be greater than simply what is measurable and I suggest, with some liberal arm-waving, that a K.i cutoff of  ~100 nM might be more useful (a K.i value of 10 μM is usually measurable provided that the inhibitor is adequately soluble in assay buffer).] Seeing SARs over 1–2 log units of activity resulting from core, substitution, and warhead changes is an important quality criterion for covalent probe molecules. [The authors need to be clearer about which ‘activity’ they are referring to (differences in K.i and k.inact values between compounds are likely to be greater than the corresponding differences in k.inact/K.i values). The criterion “SAR for covalent and non-covalent interactions” shown in Figure 2 is nonsensical.]

3.3. Chemical Matter Criteria for Degrader Probes

When selecting chemical degrader probes, it is recommended that a chemist critically assesses the chemical structure of the degrader for the presence of chemical groups that impart polypharmacology or interfere with assay read-outs (PAINs motifs). (78) [I certainly agree that chemists should critically assess chemical structures of probes and, if performing a critical assessment of this nature for a degrader probe, I would be taking a look in ChEMBL to see what’s known for structurally-related compounds. I consider the risk of discarding acceptable chemical matter on the basis of matches with PAINS substructures to be low although there’s a lot more to critical assessment of chemical structures than simply checking for matches against PAINS substructures. My view is that genuine promiscuity (as opposed to frequent hitter behavior resulting from interference with read-out) cannot generally be linked to chemical groups. As noted in K2017 the PAINS substructure model introduced in BH2010 was actually trained on the output of six AlphaScreen assays and the applicability domain of the model should be regarded as prediction of frequent-hitter behavior in this assay panel rather than interference with assay read-outs (that said the most plausible explanation for frequent-hitter behavior in the PAINS assay panel is interference with the AlphaScreen read-out by compounds that quench or react with singlet oxygen). My recommendation is that chemical matter criteria for chemical probes should be specified entirely in terms of measured data and the models used to select/screen potentially acceptable chemical matter should not be included in the chemical matter criteria.] 

This is a good point to wrap up my contribution to the important scientific discussion that H2023 is intended to jumpstart. While some of what I've written might be seen as nitpicking please bear in mind that quality criteria for chemical probes need to be defined precisely in order to be useful to the chemical biology and medicinal chemistry communities.

Sunday, 19 November 2023

On the misuse of chemical probes

It’s now time to get back to chemical probes and I’ll be taking a look at S2023 (Systematic literature review reveals suboptimal use of chemical probes in cell-based biomedical research) which has already been reviewed in blog posts from Practical Fragments, In The Pipeline and the Institute of Cancer Research. Readers of this blog are aware that PAINS filters usually crop up in posts on chemical probes but there are other things that I want to discuss and, in any case, references to PAINS in S2023 are minimal. Nevertheless, I’ll still stress that a substructural match of a chemical probe with a PAINS filter does not constitute a valid criticism of a chemical probe (it simply means that the chemical structure of the chemical probe shares structural features with compounds that have been claimed to exhibit frequent-hitter behaviour in a panel of six AlphaScreen assays) and one is more likely to encounter a bunyip than a compound that has actually been shown to exhibit pan-assay interference.

The authors of S2023 claim to have revealed “suboptimal use of chemical probes in cell-based biomedical research” and I’ll start by taking a look at the abstract (my annotations are italicised in red):

Chemical probes have reached a prominent role in biomedical research, but their impact is governed by experimental design. To gain insight into the use of chemical probes, we conducted a systematic review of 662 publications, understood here as primary research articles, employing eight different chemical probes in cell-based research. [A study such as S2023 that has been claimed by its authors to be systematic does need to say something about how the eight chemical probes were selected and why the literature for this particular selection of chemical probes should be regarded as representative of chemical probes literature in general.] We summarised (i) concentration(s) at which chemical probes were used in cell-based assays, (ii) inclusion of structurally matched target-inactive control compounds and (iii) orthogonal chemical probes. Here, we show that only 4% of analysed eligible publications used chemical probes within the recommended concentration range and included inactive compounds as well as orthogonal chemical probes. [I would argue that failure to use a chemical probe within a recommended concentration range is only a valid criticism if the basis for the recommendation is clearly articulated.] These findings indicate that the best practice with chemical probes is yet to be implemented in biomedical research. [My view is that the best practice with chemical probes is yet to be defined.] To achieve this, we propose ‘the rule of two’: At least two chemical probes (either orthogonal target-engaging probes, and/or a pair of a chemical probe and matched target-inactive compound) to be employed at recommended concentrations in every study. [The authors of S2023 do seem to moving the goalposts since the they’ve criticized studies for not using structurally matched target-inactive control compounds but are saying that using an additional orthogonal target-engaging probe makes it acceptable not to use a structurally matched target-inactive control compound. This  suggestion does appear to contradict the Chemical Probes Portal criteria for 'classical' modulators which do require the use of a control compound  defined as having a "similar structure with similar physicochemistry, non-binding against target".]

The following sentence does set off a few warning bells for me:

The term ‘chemical probe’ distinguishes compounds used in basic and preclinical research from ‘drugs’ used in the clinic, from the terms ‘inhibitor’, ‘ligand’, ‘agonist’ or ‘antagonist’ which are molecules targeting a given protein but are insufficiently characterised, and also from the term ‘probes’ which is often referring to laboratory reagents for biophysical and imaging studies.

First, the terms 'compound' and 'molecule' are not interchangeable and I would generally recommend using 'compound' when talking about biological activity or affinity. A more serious problem is that the authors of S2023 seem to be getting into homeopathic territory by suggesting that chemical probes are not ligands and this might have caused Paul Ehrlich (who died 26 years before Kaiser Wilhelm II) to spit a few feathers.  Drugs and chemical probes are ligands for their targets by virtue of binding to their targets (the term 'ligand' is derived from the Latin 'ligare' which means 'to bind' and a compound can be a ligand for one target without necessarily being a ligand for another target) while the terms 'inhibitor', 'agonist' and 'antagonist' specify the consequences of ligand binding. I was also concerned by the use of the term 'in cell concentration' in S2023 given that uncertainty in intracellular concentration is an issue when working with chemical probes (as well as in PK-PD modelling).  Although my comments above could be seen as nit-picking these are not the kind of errors that authors can afford to make if they’re going to claim that their “findings indicate that the best practice with chemical probes is yet to be implemented in biomedical research”.

Let’s take a look at the criteria by which the authors of S2023 have assessed the use of chemical probes. They assert that “Even the most selective chemical probe will become non-selective if used at a high concentration” although I think it’d be more correct to state that the functional selectivity of a probe depends on binding affinity of the probe for target and anti-targets as well as the concentration of the probe (at its site of action). Selectivity also depends on the concentration of anything that binds competitively with the probe and, when assessing kinase selectivity, it can be argued that assays for ATP-competitive kinase inhibitors should be run at a typical intracellular ATP concentration (here’s a recent open access review on intracellular ATP concentration). The presence of serum in cell-based assays should also be considered when setting upper concentration limits since chemical probes may bind to serum proteins such as albumin which means that the concentration of a compound that is ‘seen’ by the cells is lower than the total concentration of the compound in the assay. In my experience binding to albumin tends to increase with lipophilicity and is also favored by the presence of an acidic group such as carboxylate in a molecular structure.

I’m certainly not suggesting that chemical probes be used at excessive concentrations but if you’re going to criticise other scientists for exceeding concentration thresholds then, at very least, you do need to show that the threshold values have been derived in an objective and transparent manner. My view that it would not be valid to criticise studies publicly (or in peer review of submitted manuscripts) simply because the studies do not comply with recommendations made by the Chemical Probes Portal. It is significant that the recommendations from different groups of chemical probe experts with respect to the maximum concentration at which UNC1999 should be used differ by almost an order of magnitude:

As the recommended maximal in-cell concentration for UNC1999 varies between the Chemical Probes Portal and the Structural Genomics Consortium sites (400 nM and 3 μM, respectively), we analysed compliance with both concentrations.

One of the eight chemical probes featured in S2023 is THZ1 which is reported to bind covalently to CDK7 and the electrophilic warhead is acrylamide-based, suggesting that binding is irreversible. Chemical probes that form covalent bonds with their targets irreversibly need to be considered differently to chemical probes that engage their targets reversibly (see this article). Specifically, the degree of target engagement by a chemical probe that binds irreversibly depends on time as well as concentration (if you wait long enough then you’ll achieve 100% inhibition). This means that it’s not generally possible to quantify selectivity or to set concentration thresholds objectively for chemical probes that bind to their targets irreversibly. It’s not clear (at least to me) why an irreversible covalent inhibitor such as THZ1 was included as one of the eight chemical probes covered by the S2023 study so I checked to see what the Chemical Probes Portal had to say about THZ1 and something doesn’t look quite right.  The on-target potency is given as a Kd (dissociation constant which is a measure of affinity) value of 3.2 nM and the potency assay is described as “time-dependent binding established supporting covalent mechanism”.  However, Kd is a measure of affinity (and therefore not a time-dependent) and my understanding is that it is generally difficult to measure Kd for irreversible covalent inhibitors which are typically characterized by kinact (inactivation rate constant) and Ki (inhibition constant) values obtained from analysis of enzyme inhibition data. The off-target potency of THZ1 is summarized as “KiNativ profiling against 246 kinases in Loucy cells was performed showing >75% inhibition at 1 uM of: MLK3, PIP4K2C, JNK1, JNK2, JNK3, MER, TBK1, IGF1R, NEK9, PCTAIRE2, and TBK1, but in vitro binding to off-target kinases was not time dependent indicating that inhibition was not via a covalent mechanism”. The results from the assays used to measure on-target and off-target potency for THZ1 do not appear to be directly comparable.

It’s now time to wrap up and I suggest that it would not be valid to criticise (either publicly or in peer review) a study simply on the grounds that it reported results of experiments in which a chemical probe was used at a concentration exceeding a recommended maximum value. The S2023 authors assert that an additional orthogonal target-engaging probe can be substituted for a matched target-inactive control compound but this appears to contradict criteria for classical modulators given by the Chemical Probes Portal.

Wednesday, 22 February 2023

Structural alerts and assessment of chemical probes

 << previous |

I’ll wrap up (at least for now) the series of posts on chemical probes by returning to the use of cheminformatic models for assessment of the suitability of compounds for use as chemical probes. My view is that there is currently no cheminformatic model, at least in the public domain, that is usefully predictive of the suitability (or unsuitability) of compounds for use as chemical probes and that assessments should therefore be based exclusively on experimental measurements of affinity, selectivity etc. Put another way, acceptable chemical probes will need to satisfy the same criteria regardless of the extent to which they offend the tastes of PAINS filter evangelists (and if PAINS really are as bad as the evangelists would have us believe then they’re hardly going to satisfy these acceptability criteria). My main criticism of PAINS filters (summarized in this comment on the ACS assay interference editorial) is that there is a significant disconnect between dogma and data. 

I’ll start by saying something about cheminformatics since, taken together, the PAINS substructures can be considered as a cheminformatic predictive model. If you’re using a cheminformatic predictive model then you also need to be aware that it will have an applicability domain which is limited by the data used to train and validate the model. Consider, for example, that you have access to a QSAR model for hERG blockade that has been trained and validated using only data for compounds that are protonated at the assay pH.  If you base decisions on predictions for compounds that are neutral under assay conditions then you’d be using the model outside its applicability domain (and therefore in a very weak position to blame the modelers if the shit hits the fan). While cheminformatic predictive models might (or might not) help you get to a desired endpoint more quickly you’ll still need experimental measurements in order to know that you have indeed got the desired end point.

But let’s get back to PAINS filters which were introduced in this 2010 study. PAINS is an acronym for pan-assay interference compounds and you could be forgiven for thinking that PAINS filters were derived by examining chemical structures of compounds that had been shown to exhibit pan-assay interference. However, the original PAINS study doesn’t appear to present even a single example of a compound that is shown experimentally to exhibit pan-assay interference and the medicinal chemistry literature isn’t exactly bursting at the seams with examples of such compounds.

The data set on which the PAINS filters were trained consisted of the hits (assay results in which the response was greater than a threshold when the compound was tested at a single concentration) from six high-throughput screens, each of which used AlphaScreen read-out. Although PAINS filters are touted as predictors of pan-assay interference it would be more accurate to describe them as predictors of frequent-hitter behavior in this particular assay panel (as noted in a previous post promiscuity generally increases as the activity threshold is made more permissive). From a cheminformatic perspective the choice of this assay panel appears to represent a suboptimal design of an experiment to detect and characterize pan-assay interference (especially given that data from “more than 40 primary screening campaigns against enzymes, ion channels, protein-protein interactions, and whole cells” were available for analysis). Those who advocate the use of PAINS filters for the assessment of the suitability of compounds for use as chemical probes (and the Editors-in-Chief of more than one ACS journal) may wish to think carefully about why they are ignoring a similar study based on a larger, more diverse (in terms of targets and read-outs) data set that had been published four years before the PAINS study.     

Although a number of ways in which potential nuisance compounds can reveal their dark sides are discussed in the original PAINS study the nuisance behavior is not actually linked to the frequent-hitter behavior reported for compounds in the assay panel. Also, it can be safely assumed that none of the six protein-protein interaction targets of the PAINS assay panel feature a catalytic cysteine and my view is that any frequent-hitter behavior that is observed in the assay panel for ‘cysteine killers’ is more likely to be due to reaction with (or quenching of) singlet oxygen. It’s also worth pointing out that when compounds are described as exhibiting pan-assay interference (or as frequent hitters) that the relevant nuisance behavior has often been predicted (or assumed) as opposed to being demonstrated with measured data.  I would argue that even a ‘maximal PAINS response’ (the compounds is actually observed as a hit in each of the six assays of the PAINS assay panel) would not rule out the use of a compound as a chemical probe.

I have argued on cheminformatic grounds that it’s not appropriate to use PAINS filters for assessment of potential probes but there’s another reason that those seeking to set standards for chemical probes shouldn’t really be endorsing the use of PAINS filters for this purpose. “A conversation on using chemical probes to study protein function in cells and organisms” that was recently published in Nature Communications stresses the importance of Open Science. However, the PAINS structural alerts were trained on proprietary data and using PAINS filters to assess potential chemical probes will ultimately raise questions about the level of commitment to Open Science. I made a very similar point in my comment on the ACS assay interference editorial (Journal of Medicinal Chemistry considers the publication of analyses of proprietary data to be generally unacceptable).

Let’s take a look at “The promise and peril of chemical probes” that was published in Nature Chemical Biology in 2015. The authors state:

“We learned that many of the chemical probes in use today had initially been characterized inadequately and have since been proven to be nonselective or associated with poor characteristics such as the presence of reactive functionality that can interfere with common assay features [3] (Table 2). The continued use of these probes poses a major problem: tens of thousands of publications each year use them to generate research of suspect conclusions, at great cost to the taxpayer and other funders, to scientific careers and to the reliability of the scientific literature.”

Let’s take a look at Table 2 (Examples of widely used low-quality probes) from "The promise and peril of chemical probes". You’ll see “PAINS” in the problems column of Table 2 for two of the six low-quality probes in and this rings a number of alarm bells for me. Specifically, it is asserted that flavones are “often promiscuous and can be pan-assay interfering (PAINS) compounds” and Epigallocatechin-3-gallate is a “promiscuous PAINS compound” which raises a number of questions. Were the (unspecified) flavones and Epigallocatechin-3-gallate actually observed to be promiscuous and if so what activity threshold was used for quantifying promiscuity? Were any of the (unspecified) flavones or Epigallocatechin-3-gallate actually observed to exhibit pan-assay interference?  Were affinity and selectivity measurements actually available for the (unspecified) flavones or Epigallocatechin-3-gallate?

I’ll conclude the post by saying something about cheminformatic predictive models. First, to use a cheminformatic predictive model outside its applicability domain is a serious error (and will cast doubts on the expertise of anybody doing so). Second, predictions might (or might not) help you get to a desired end point but you’ll still need measured data to establish that you’ve got to the desired end point or that a compound is unfit for a particular purpose.  

Monday, 2 January 2023

Assessment of chemical probes

| next >>

I’ll be taking a look at some of the criteria, specifically structural alerts, by which chemical probes are assessed and here’s the link to the Chemical Probes Portal. Before getting into the post there are a couple of points that I need to stress. First, structural alerts derived from analysis of screening hits (defined as responses that exceed a threshold when assayed at a particular concentration) are not necessarily useful for assessing higher affinity compounds for which concentration responses have been determined. Second, chemical probes will have to satisfy the same set of acceptability criteria whether or not they trigger structural alerts.      

I’ll start by commenting on “A conversation on using chemical probes to study protein function in cells and organisms” that was recently published in Nature Communications since it was this article that triggered the blog post.  I consider most of the views expressed in the in the article to be sound although I disagree with much of what is stated in the following paragraph:

“The first essential thing that needs to be done is to eliminate the really bad nuisance compounds, which can have problematic behavior—like being non-specifically very reactive with proteins; forming colloidal aggregates that non-specifically adsorb and inactivate proteins; exerting toxicity toward cells, for example through a membrane damaging effect called phospholipidosis; or exhibiting spectral or fluorescence properties that interfere with the biological assay read-out. These undesirable compounds are often referred to as Pan Assay Interference or PAINS compounds, as highlighted by Jonathan Baell [4]. There are software filters or algorithms available that should be used routinely to identify any risk of such chemical promiscuity and simple lab assays should be run to check for the various problematic properties we mentioned. Such compounds should never be considered further or used as chemical probes. They should be excluded from compound libraries. Yet many are sold by commercial vendors as chemical probes and widely used.”

In 2017 a number of ACS journals simultaneously published “The Ecstasy and Agony of Assay Interference Compounds” editorial and I believe that a number of points raised in a comment on this editorial are still relevant to dealing with nuisance compounds. In the comment, I classified bad behavior of screening ‘actives’ as Type 1 (compound hits in the assay but does not affect target function) and Type 2 (compound affects target function through an undesirable mechanism of action). These are two very different problems and each requires very different solutions. Type 1 behavior, which can also be described as interference with read-out, is primarily a problem from the perspective of analysis of high-throughput screening (HTS) output because you don’t know whether observed ‘activity’ is real or not. From the perspective of probe promiscuity, Type 1 behavior is much less of a problem than Type 2 behavior because the ‘activity’ is not real. If you’re trying to decide whether a potential chemical probe is acceptable then genuine activity at 50 nM against another protein is going to hurt a whole lot more than responses of >50% in several assays at a test concentration of 10 μM. 

It is asserted in the conversation that there are “software filters or algorithms available that should be used routinely to identify any risk of such chemical promiscuity”. When recommending their use of predictive models for assessment of potential probes, it’s important to be aware of their inherent limitations. Specifically, models derived from analysis of data have applicability domains that are imposed by the data used to build the models. For example, PAINS filters were derived from analysis of the output of six screens that all use the same read-out (AlphaScreen) and this limits the applicability domain of the PAINS filter model to prediction of frequent-hitter behavior in AlphaScreen assays. It is asserted in the conversation that commercial vendors are selling compounds as chemical probes that are unfit for purpose and I strongly recommend that anybody making such assertions should carefully examine the supporting evidence.  I would argue that sharing structural features with compounds (for which structures that have not been disclosed) that have been observed to exhibit frequent-hitter behavior when screened at a single concentration (e.g., 10 μM) would not credibly support an assertion that a compound is unsuitable for use as a chemical probe. A specific criticism I would make of the way that structural alerts (especially those derived using proprietary data) are used is that it is sometimes suggested, for example in the ACS assay interference editorial, that HTS hits that don’t trigger structural alerts can be checked less thoroughly than hits that do trigger structural alerts.

The Information Centre of the Chemical Probes Portal includes a “Toxicophores and PAINS Alerts” section in which it is correctly stated that “the presence of the toxicophore or PAINS substructures within the chemical structure of a compound does not necessarily mean that it will be non-specifically active or toxic, or give rise to assay interference”. The “Toxicophores and PAINS Alerts” section might work better as a “Structural Alerts” section and the toxicophores citation appears to be incorrect (reference 10 actually cites an article on toxicity risks associated with excessive lipophilicity).  If doing this, I would recommend saying something about the applicability domains of any structural alerts that are highlighted and considering the inclusion of Aggregator Advisor (link to article)  and BadApple (here's link to article)  

Alternatively, it might be an idea to create separate “Nuisance Compounds” and “Toxicophores” sections because these are very different problems. I would generally recommend the use of the term “nuisance compounds” since PAINS and colloidal aggregators are sometimes treated as separate categories of bad actor, as is the case in the ACS assay interference editorial, and the criteria for labelling compounds as PAINS are ambiguous.  It would certainly be useful to include some reviews on assay interference, such as this one, in a “Nuisance Compounds” section. I quite like this article by former colleagues which shows how interference with read-out can be assessed and even corrected for.  As for a “Structural Alerts” section, the applicability domains of any predictive models should be indicated so people don’t end up using models that have been trained using hits from screening at 10 μM to assess probes with 20 nM affinity.

This is a good point at which to wrap up and it’s worth stressing that the essence of the criticism of PAINS filters is simply that the rhetoric is not supported by the data. Those like me who are critical of the way that PAINS filters are used are certainly not suggesting that screening hits all smell of roses (back in 1995 I used the Daylight toolkits to build the SMARTS-matching software that was used in the Zeneca ‘de-crapper’ and colleagues also created the Flush software) nor are we denying that assay interference is a serious problem. Although I believe that it is certainly helpful to have scientists who have worked with HTS data share their experiences and opinions with respect to hit quality, I would argue that there are dangers in giving such opinions too much weight (this article may be of interest) especially when data that might be used to justify the opinions are proprietary. Specifically, I would strongly advise against making statements that a compound is unfit for use as a chemical probe unless the assertion is supported by measured data in the public domain for the compound in question.

I’ll leave it there for now. In the next post on chemical probes, I’ll be taking a look at permeability.

Monday, 13 April 2015

Expertitis

I will never call myself an expert for to do so would be to take the first step down a very slippery slope.  It is important to remember that each and every expert has both an applicability domain and a shelf life.  It’s not the experts themselves to which I object but what I’ll call ‘expert-driven decision-making’ and the idea that you can simply delegate your thinking to somebody else.

I’m going to take a look at an article that describes attempts to model an expert’s evaluation of chemical probes identified by NIH-funded high throughput screening.  The study covers some old ground and one issue facing authors of articles like these is how to deal with the experts in what might be termed a ‘materials and methods context’.   Experts who are also coauthors of studies like these become, to some extent, self-certified experts.   One observation that can be made about this article is that its authors appear somewhat preoccupied with the funding levels for the NIH chemical probe initiative and I couldn't help wondering about how this might have shaped or influenced the analysis.

A number of approaches to modeling the expert’s assessment of the 322 probe compounds of which 79% were considered to be desirable.   The approaches used by the authors ranged from simple molecular property filtering to more sophisticated machine learning models.  I noted two errors (missing molar energy units; taking logarithm of quantity with units) in the formula for ligand efficiency and it’s a shame they didn’t see our article on ligand efficiency metrics which became available online about six weeks before they submitted their article (the three post series starting here may be helpful).  The authors state, “PAINS is a set of filters determined by identifying compounds that were frequent hitters in numerous high throughput screens” which is pushing things a bit because the PAINS filters were actually derived from analysis of the output from six high throughput screening campaigns (this is discussed in detail in three-post series that starts here).  Mean pKa values of 2.25 (undesirable compounds) and 3.75 (desirable compounds) were reported for basic compounds and it certainly wasn’t clear to me how compounds were deemed to be basic given that these values are well below neutral pH. In general, one needs to be very careful when averaging pKa values.  While these observations might be seen as nit-picking, using terms like ‘expert’, ‘validation’ and ‘due diligence’ in title and abstract does set the bar high.

A number of machine learning models were described and compared in the article and it’s worth saying something about models like these.  A machine learning model is usually the result of an optimization process.  When we build a machine learning model, we search for a set of parameters that optimizes an objective such as fit or discrimination for the data with which we train the model.  The parameters may be simple coefficients for parameters (like in a regression model) but they might also be threshold values for rules.  The more parameters you use to build a model (machine learning or otherwise), the more highly optimized the resulting model will be and we use the term ‘degrees of freedom’ to say how many parameters we’ve used when training the model.   You have to be very careful when comparing models that have different numbers of degrees of freedom associated with them and one criticism that I would make of machine learning models is that the number of degrees of freedom is rarely (if ever) given.  Over-fitting is always a concern with models and it is customary to validate machine learning models using one or more of a variety of protocols. Once a machine learning model has been validated, number of degrees of freedom is typically considered to be a non-issue. Clustering in data can cause validation to make optimistic assessments of model quality and the predictive chemistry community does need to pay more attention to Design of Experiments. Here’s a slide that I sometimes use in molecular design talks.





Let’s get back to the machine learning models in the featured article.  Comparisons were made between models (see Figure 4 and Table 5 in the article) but no mention is made of numbers of degrees of freedom for the models.   I took a look in the supplementary information to see if I could get this information by looking at the models themselves and discovered that the models had not actually been reported. In fact, the expert’s assessment of the probes had not been reported either and I don't believe that this article scores highly for either reproducibility or openness.   Had this come to me as a manuscript reviewer, the response would have been swift and decisive and you probably wouldn’t be reading this blog post. How much weight should those responsible for NIH chemical probes initiative give to the study?  I’d say they can safely ignore it because the data set is proprietary and models trained on it are only described and not actually specified.  Had the expert's opinion on the desirability (or otherwise) of the probes been disclosed then it would have been imprudent for the NIH folk to ignore what the expert had to say. At the same time, it's worth remembering that we seek different things from probes and from drugs and one expert's generic opinion of a probe needs to placed in the context of any specific design associated with the probe's selection.

However, there are other reasons that the NIH chemical probes folk might want to be wary of data analysis from this source and I'll say a bit more about these in the next post.